Commit 05153315 authored by kbk's avatar kbk
Browse files

re-introduce temperature limitation - -DHAMSOM_SVP

parent 4475cd3d
!$Id: exchange_coefficients.F90,v 1.9 2005-01-13 09:49:37 kbk Exp $
!$Id: exchange_coefficients.F90,v 1.10 2005-04-19 12:11:33 kbk Exp $
#include "cppdefs.h"
!-----------------------------------------------------------------------
!BOP
......@@ -65,7 +65,10 @@
! Original author(s): Karsten Bolding
!
! $Log: exchange_coefficients.F90,v $
! Revision 1.9 2005-01-13 09:49:37 kbk
! Revision 1.10 2005-04-19 12:11:33 kbk
! re-introduce temperature limitation - -DHAMSOM_SVP
!
! Revision 1.9 2005/01/13 09:49:37 kbk
! wet bulb works, es is global, cleaning - Stips
!
! Revision 1.8 2003/12/16 17:35:33 kbk
......@@ -115,8 +118,9 @@
REALTYPE :: x
REALTYPE :: ta,ta_k,tw,tw_k
REALTYPE :: twet,rh
REALTYPE :: dew
REALTYPE :: rh
REALTYPE :: twet,twet_k
REALTYPE :: dew,dew_k
REALTYPE :: x1,x2,x3
!EOP
!-----------------------------------------------------------------------
......@@ -168,7 +172,8 @@
#endif
#ifdef HAMSOM_SVP
x = 17.67*tw/(tw+243.5)
x = (18.729 - (min(tw_k,300.)-273.15)/227.3)* &
(min(tw_k,300.)-273.15)/(max(tw_k,240.)-273.15+257.87)
es = 611.2 * exp(x)
#else
es = a1 +tw*(a2+tw*(a3+tw*(a4+tw*(a5+tw*(a6+tw*a7)))))
......@@ -180,7 +185,7 @@
! see ../ncdf/ncdf_meteo.F90 for defined constants
select case (hum_method)
case (1)
! specifc humidity in kg/kg is given
! specific humidity in kg/kg is given
qa = hum
! aktual water vapor pressure
ea = qa *airp/(const06+0.378*qa)
......@@ -207,36 +212,24 @@
! use dew in degC
if (hum .lt. 100.) then
dew = hum
dew_k = hum+KELVIN
else
dew = hum - KELVIN
dew = hum-KELVIN
dew_k = hum
end if
#ifdef HAMSOM_SVP
x = 17.67*dew/(dew+243.5)
ea = 611.2 * exp(x)
#else
ea = a1 +dew*(a2+dew*(a3+dew*(a4+dew*(a5+dew*(a6+dew*a7)))))
ea = ea * 100.0 ! Conversion millibar --> Pascal
#endif
#if 0
! This is kept for reference - original HAMSOM formulation
! AS see what happens if coding is done without understanding..
x1 = (18.729 - (min(dew,300.*_ONE_)-273.15)/227.3)
x2 = (min(dew,300.*_ONE_)-273.15)
x3 = (max(dew,200.*_ONE_)-273.15+257.87)
#ifdef HAMSUN_SVP
x1 = (18.729 - (min(dew_k,300.*_ONE_)-273.15)/227.3)
x2 = (min(dew_k,300.*_ONE_)-273.15)
x3 = (max(dew_k,200.*_ONE_)-273.15+257.87)
ea = 611.21*exp(x1*x2/x3)
!KBK ea = 611.21*exp((18.729 - (min(dew,300.)-273.15)/227.3)* &
!KBK (min(dew,300.)-273.15)/(max(dew,200.)-273.15+257.87))
x1 = (18.729 - (min(ta_k,300.*_ONE_)-273.15)/227.3)
x2 = (min(ta_k,300.*_ONE_)-273.15)
x3 = (max(ta_k,200.*_ONE_)-273.15+257.87)
es = 611.21*exp(x1*x2/x3)
!KBK es = 611.21*exp((18.729 - (min(ta_k,300.)-273.15)/227.3)* &
!KBK (min(ta_k,300.)-273.15)/(max(ta_k,200.)-273.15+257.87))
rh = 100.*ea/es
qa = 0.01*rh*qs
#endif
!AS convert actual vapor pressure to specific humidity
qa = const06*ea/(airp-0.377*ea)
case (4)
! wet bulb temperature given
! Calculate the SVP at wet bulb temp then
......@@ -245,12 +238,15 @@
! Make sure this is in degC
if (hum .lt. 100 ) then
twet=hum
twet_k=hum+KELVIN
else
twet=hum - KELVIN
twet=hum-KELVIN
twet_k=hum
end if
! saturation vapor pressure at wet bulb temperature
#ifdef HAMSOM_SVP
x = 17.67*twet/(twet+243.5)
x = (18.729 - (min(twet_k,300.)-273.15)/227.3)* &
(min(twet_k,300.)-273.15)/(max(twet_k,240.)-273.15+257.87)
ea = 611.2 * exp(x)
#else
ea = a1 +twet*(a2+twet*(a3+twet*(a4+twet*(a5+twet*(a6+twet*a7)))))
......